VERILOG2082: Port direction should be set to “inout” when port is both read and written
Summary
| Reliability | Security | Maintainability | Code attribute | Effort to fix | Tags |
|---|---|---|---|---|---|
| - | - | LOW | Intentionality | Clear | 5min | synthesis, vscode, linter, simulation |
Description
Noncompliant code example
module fly(input wire a, output b); assign a = 1; endmodule module top; wire b; fly fly1(1, b); assign b = 1; endmodule
Compliant solution
module fly(inout wire a, inout b); assign a = 1; endmodule module top; wire b; wire c = 1: fly fly1(c, b); assign b = 1; endmodule
An input net port has been coerced to 'inout' direction because it is assigned to in the instance body. Alternatively, an output net port has been coerced to 'inout' direction because it is assigned externally to the instance. Update direction in source code accordingly.
Parameters